- Transducer TypeCondenser
- Polar PatternHypercardioid
- Frequency Response
- VP89L: 40-20,000 Hz
- VP89M: 50-20,000 Hz
- VP89S: 65-20,000 Hz
- Output Impedance115.0Ω
- Sensitivity
- open circuit voltage, @ 1 kHz, typical
- -33.5 dBV/Pa[1] (21.1 mV)
- Maximum SPL (1 kHz at 1% THD[2])
- 2500Ω load: 132.0 dB SPL
- 1000Ω load: 128.5 dB SPL
- Signal-to-Noise Ratio[3]79.0 dB
- Dynamic Range (@ 1 kHz)
- 2500Ω load: 117.0 dB
- 1000Ω load: 113.5 dB
- Clipping Level (@ 1 kHz, 1% THD)
- 2500Ω load: 4.0 dBV
- 1000Ω load: 0.0 dBV
- Self Noise
- equivalent SPL, A-weighted, typical
- 15.0 dB
- Common Mode Rejection
- 20 to 20,000 Hz
- ≥70.0 dB
- Low-Frequency Filter Switch (-12 dB/oct below specified frequency)
- Flat Response: 100 Hz
- Low Frequency Rolloff: 200 Hz
- Power Requirements11–52 V DC[4] phantom power (IEC-61938), <2.0 mA
- Net Weight
- VP89L: 174 g (6.1 oz.)
- VP89M: 138 g (4.9 oz.)
- VP89S: 117 g (4.1 oz.)
- Note
- [1] 1 Pa=94 dB SPL
- [2]THD of microphone preamplifier when applied input signal level is equivalent to cartridge output at specified SPL
- [3]S/N ratio is the difference between 94 dB SPL and equivalent SPL of self noise, A-weighted
- [4]All specifications measured with a 48 Vdc phantom power supply. The microphone operates at lower voltages, but with slightly decreased headroom and sensitivity.